AMGADS
III - On Board Vehicle Methane Detection System for Alternative
Fuel Vehicles |
 |
 |
 |
 |
 |
 |

|
System
Design : Amerex Two Zone Gas Detection System
The AMGADS II vapor monitoring system utilizes advance technology
for detection of Compressed Natural Gas (CNG), Liquified Natural
Gas (LNG), Propane (LPG), Hydrogen and any other hydrocarbon
fuel vapors. The AMGADS II allows connection of two (2) sensors
and has both visual and audible alarms at Trace and Significant
gas concentration levels. Test buttons are provided for full
checking of all operations. System operation and connect sensor
operation are continually monitored and indicators are provided
for full detection. In addition, the AMGADS II Plus has an
internal relay for automatic control of auxiliary devices.
Read the Owner's Manual completely before installation.
Sensor Superiority: The
gas sensor is the heart of any gas detection system. The sensor
used in AMGADS III is 100% functionally tested and operated
for an extended period before it is shipped to the customer,
ensuring consistency and reliability while eliminating premature
failures. Amerex goes a step further in its commitment to
sensor superiority by ensuring that our sensors are resistant
to most toxic chemicals that might reduce the life of other
sensors during environmental exposure. |
Specifications:
Voltage: ..................+9
to 30 VDC Nominal
Input Currents: ........10 amps max.
Fuse Size: ...............10 amp type
AGC Fast Blow only
Current Draw: .........70 mA per sensor
@ 30 VDC
.................................300
mA max. (relay engaged)
Alarm: ......................Trace
Level = 20% Lower Explosive Limit
.................................Significant
Level = Lower Explosive Limit
Horn: ........................75 db
@ 10 cm 3 kH frequency
Relay Contacts:........5 amp max. |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |

For more information, please contact us at
sales@amerex-fire.com
Copyright © 2001 Amerex Corporation
Web Page Feedback:
webmaster@amerex-fire.com |